While hex key is in upper position, fit the spring and terminal block from below, compress the spring about 80% (not 100% as shown in the picture!), and tighten the terminal screws.

Trigger the probe by flicking the short leg past the safety-pin spring into the deployed position.

Confirm it is pushed down hard enough by the spring to activate the micro-switch - you should hear the micro-switch click.

Push from below against the probe leg until the hex key pushes back up past the safety-pin spring. Check that it retracts correctly.

You may need to bend the safety-pin spring leg to adjust the force required.

Push from below against the probe leg until the hex key pushes back up past the safety-pin spring.

Check that it retracts correctly. You may need to bend the safety-pin spring leg to adjust the force required.

Repeat several times to confirm that the probe will work reliably. You may need to oil or grease the brass rod during commissioning.